Performance Vitral's new A74 rooflight system has been designed with high performance as a standard, it provides the lowest overall system U-value available of 1.5 W/m²K.
Vitral's systems are hot box tested to prove their efficiency rather than using assumed values. We undertake U-value calculations for every project proving Part L compliance.
Natural Ventilation As with Vitral's premier system, the VRS system, The A74 does not have a carrier frame as with patent glazing or curtain walling. This means every panel is capable of opening without the need for extra framing, so maintaining low U-values, controlling costs and maximising the amount of daylight through the system.
Full Life Safety Fire Ventilation (EN12101-2) A standard feature that Vitral adopts is ensuring its system comply with EN12101-2:2003 legislation for smoke ventilation.
Vitral has developed high performance rooflight systems to meet your demands. Please use the matric below to choose the system you need:
| Features |
VRS System |
A74 System |
Benefits |
| Construction |
Stainless Steel |
Aluminium |
High quality construction that provides long term life expectancy and will not deteriorate |
| Colour |
Self coloured stainless steel |
Anodised aluminium or ppc to any RAL |
Both stainless steel and anodised aluminium blend in with other materials, both internally and externally but colour can be added to match other aspects or to comply with planning requirements |
| Typical U-value |
1.54W/m2K |
1.6W/m2K |
Part L requires 2.2W/m2K max, recommended 1.8W/m2K |
| Section Width |
48mm |
50mm |
Minimal frame means maximum light and reduces U-value |
| Section Depth |
95mm |
74mm |
| EN12101-2 Smoke Ventilation |
Yes |
Yes |
Removes the need for propriatory smoke vents |
| Additional Frame For Opening Vents |
Not required, integrated opening vents |
No visible external difference between opening panels and fixed panels |
| Self Supported Double Pitch |
Yes |
Yes |
Minimal frame means maximum light and reduces U-value |
| Air Permeability |
Class 4 at 600 Pa |
Class 4 at 600 Pa |
Complies to EN12207 |
|
more info... |
|
|
|